There was no difference between ACDR CPR and STR with regard to complications such as rib or sternal fractures, pneumothorax, or haemothorax (RR 1.09, 95% CI 0.86 to 1.38). However, assessment of neurological outcome was limited, and few participants had neurological damage. The Thumper CPR System is used to perform. The pooled RR of neurological impairment of any severity was 1.71 (95% CI 0.90 to 3.25), with a non-significant trend to more frequent severe neurological damage in survivors of ACDR CPR (RR 3.11, 95% CI 0.98 to 9.83). Federal law restricts this device to sale by or on the order of a licensed medical practitioner. There were no differences between ACDR CPR and STR for mortality either immediately (RR 0.98, 95% confidence interval (CI) 0.94 to 1.03) or at hospital discharge (RR 0.99, 95% CI 0.98 to 1.01). Out-of-hospital trials cumulated 4162 participants. Learn how Strykers devices help professional responders in the field to the hospital in providing high-quality CPR, every step of the way. Indications for Use: (same as Predicate device Thumper Model 1007) 'This device is used to perform Cardiopulmonary Resuscitation (CPR) on adult patients and only adult patients in cases of clinical death as defined by a lack of spontaneous breathing and pulse. Both found no differences between ACDR CPR and STR in any outcome. CPR devices High-quality and minimally interrupted CPR is a major link in the chain of survival for good patient outcomes.
THUMPER CPR DEVICE MANUAL
Failure to initiate compressions when first turned on, if improperly shut down-Operator Manual updated to include proper shut down. All units with a manual configuration (as opposed to a pneumatic configuration). Michigan Instruments Thumper Mechanical CPR Device Model 1007. The two in-hospital studies were different in quality and size (773 and 53 participants). Class 3 Device Recall Thumper mechanical cardiopulmonary resuscitator. It is typically powered from medical gas cylinders or a medical gas pipeline system and may consist of a solid base. Allocation concealment was adequate in four studies. A pneumatically-powered external device designed for the application of rhythmic compression to the chest in the region of the heart to provide blood flow during treatment of cardiac arrest cardiopulmonary resuscitation (CPR).
THUMPER CPR DEVICE PDF
In the end, we included 10 trials in this review: Eight were in out-of-hospital settings one was set in-hospital only and one had both in-hospital and out-of-hospital components. Human powered mechanical cpr device with optimized waveform characteristics Download PDF Info Publication number WO2013188175A1. In this update, 27 new related publications were found, but they did not all fulfil inclusion criteria or concerned participants already reported in previous publications.